{"id":32675,"date":"2022-04-13T07:55:35","date_gmt":"2022-04-13T05:55:35","guid":{"rendered":"https:\/\/campusvygon.com\/es\/?p=32675"},"modified":"2025-07-21T13:16:23","modified_gmt":"2025-07-21T11:16:23","slug":"canulas-extraccion-precision-enfit-neonatos","status":"publish","type":"post","link":"https:\/\/campusvygon.com\/es\/canulas-extraccion-precision-enfit-neonatos\/","title":{"rendered":"C\u00c1NULAS DE EXTRACCI\u00d3N: \u00bfSU USO AUMENTA LA PRECISI\u00d3N DE LA DOSIS DE LOS CONECTORES ENFit EN NEONATOS?"},"content":{"rendered":"\n<p>La llegada de los conectores ENFit, conectores \u201cseguros\u201d de nutrici\u00f3n enteral a las unidades de neonatolog\u00eda supuso el fin de los conocidos como \u201cerrores de conexi\u00f3n\u201d. Es decir, a partir de su incorporaci\u00f3n, ha resultado imposible conectar accidentalmente sistemas de administraci\u00f3n con objetivos diferentes (p. ej.: sistemas enterales con intravenosos).<\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/formacion.campusvygon.com\/es\/cursos\/curso-pendiente-de-acreditacion---nutricion-enteral-segura-en-neonatos-86?edicion=101&amp;tab=info\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"512\" src=\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/twitter-facebook-2.jpg\" alt=\"\" class=\"wp-image-32493\" srcset=\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/twitter-facebook-2.jpg 1024w, https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/twitter-facebook-2-980x490.jpg 980w, https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/twitter-facebook-2-480x240.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/a><\/figure>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>No obstante, la incorporaci\u00f3n de ENFit ha planteado, tambi\u00e9n, grandes desaf\u00edos en cuanto a la administraci\u00f3n de f\u00e1rmacos en estos peque\u00f1os pacientes. El cambio de conector macho\/hembra ha dado lugar a una mayor apertura en el cono de las jeringas, tanto en las jeringas ENFit cl\u00e1sicas como en las jeringas de punta enteral alternativa. Este hecho hace que la medicaci\u00f3n puede quedar atrapada en la zona del cono.<\/p>\n\n\n\n<p>Se ha demostrado, y as\u00ed lo confirma la propia Organizaci\u00f3n Internacional de est\u00e1ndares (ISO) que <strong>estos sistemas, por tanto, dar lugar a dosis inexactas de la f\u00f3rmula administrada<\/strong> (desplazamiento de volumen muerto medio 0.148 ml.).<\/p>\n\n\n\n<p><strong>Este desplazamiento del fluido es especialmente inaceptable cuando se administran f\u00e1rmacos orales en peque\u00f1as dosis a pacientes neonatales<\/strong> ya que los efectos de la sobredosificaci\u00f3n pueden causar complicaciones irreversibles, incluso, la muerte cuando se trata de medicamentos considerados peligrosos.<\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-cover\" style=\"min-height:246px;aspect-ratio:unset;\"><span aria-hidden=\"true\" class=\"wp-block-cover__gradient-background has-background-dim\"><\/span><img loading=\"lazy\" decoding=\"async\" width=\"1238\" height=\"696\" class=\"wp-block-cover__image-background wp-image-32678\" alt=\"C\u00c1NULAS DE EXTRACCI\u00d3N: \u00bfSU USO AUMENTA LA PRECISI\u00d3N DE LA DOSIS DE LOS CONECTORES ENFit EN NEONATOS?\" src=\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/Captura-de-pantalla-2022-04-12-094533.png\" data-object-fit=\"cover\" srcset=\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/Captura-de-pantalla-2022-04-12-094533.png 1238w, https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/Captura-de-pantalla-2022-04-12-094533-980x551.png 980w, https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/Captura-de-pantalla-2022-04-12-094533-480x270.png 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1238px, 100vw\" \/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<p class=\"has-text-align-center has-medium-font-size\">ART\u00cdCULOS RELACIONADOS<\/p>\n\n\n\n<p class=\"has-text-align-center\"><a href=\"https:\/\/campusvygon.com\/es\/nutricion-enteral-errores-conexion\/\" target=\"_blank\" rel=\"noreferrer noopener\">Nutrici\u00f3n enteral en neonatos: elecci\u00f3n de un sistema seguro y espec\u00edfico que evite los errores de conexi\u00f3n (campusvygon.com\/es)<\/a><\/p>\n\n\n\n<p class=\"has-text-align-center\"><a href=\"https:\/\/campusvygon.com\/es\/nutricion-enteral-errores-conexion\/\" target=\"_blank\" rel=\"noreferrer noopener\">Nutrici\u00f3n enteral en neonatos: elecci\u00f3n de un sistema seguro y espec\u00edfico que evite los errores de conexi\u00f3n (campusvygon.com\/es)<\/a><\/p>\n\n\n\n<p class=\"has-text-align-center\"><a href=\"https:\/\/campusvygon.com\/es\/protocolo-lactancia-materna\/\" target=\"_blank\" rel=\"noreferrer noopener\">Protocolo de lactancia materna: protecci\u00f3n y apoyo hospitalario &#8211; Campus Vygon<\/a><\/p>\n\n\n\n<p class=\"has-text-align-center\"><a href=\"https:\/\/campusvygon.com\/es\/iso-803693-enfit-nutricion-enteral\/\" target=\"_blank\" rel=\"noreferrer noopener\">Nutrici\u00f3n Enteral: De la preocupaci\u00f3n a la norma ISO 80369-3, ENFIT &#8211; Campus Vygon<\/a><\/p>\n\n\n\n<p class=\"has-text-align-center\"><a href=\"https:\/\/campusvygon.com\/es\/enfit-no-seguro-neonatos\/\" target=\"_blank\" rel=\"noreferrer noopener\">ENFit un sistema incompatible con la seguridad neonatal (campusvygon.com\/es)<\/a><\/p>\n\n\n\n<p class=\"has-text-align-center\"><a href=\"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/\" target=\"_blank\" rel=\"noreferrer noopener\">ENFit un sistema incompatible con la seguridad neonatal II (campusvygon.com\/es)<\/a><\/p>\n\n\n\n<p class=\"has-text-align-center\"><a href=\"https:\/\/campusvygon.com\/es\/jeringa-ldt-sobredosis\/\" target=\"_blank\" rel=\"noreferrer noopener\">\u00bfPor qu\u00e9 la jeringa LDT NO elimina el riesgo de sobredosis en neonatos? (campusvygon.com\/es)<\/a><\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Con el objetivo de evitar esta situaci\u00f3n, se han buscado alternativas para obtener una dosificaci\u00f3n m\u00e1s segura, como la que se requiere en las UCIN. Entre ellas, se habla de protocolizar el uso de c\u00e1nulas\/ pajitas de extracci\u00f3n. Pero \u00bfrealmente aumenta la precisi\u00f3n de la dosis el uso de estas c\u00e1nulas?<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>\u00bfC\u00d3MO FUNCIONA TE\u00d3RICAMENTE LA C\u00c1NULA DE EXTRACCI\u00d3N EN LA CARGA DE JERINGAS?<\/strong><\/h3>\n\n\n\n<p>El uso de la c\u00e1nula, en teor\u00eda, deber\u00eda suponer una reducci\u00f3n del riesgo de sobredosis, siguiendo las instrucciones:<\/p>\n\n\n\n<ol class=\"wp-block-list\" type=\"1\"><li>Conectar la c\u00e1nula a la jeringa y cargarla con el dispositivo correctamente ajustado<\/li><li>Desconectar la c\u00e1nula una vez se haya hecho el reajuste eliminado las burbujas o aire que queden en el interior del dispositivo<\/li><li>Observar el l\u00edquido que queda en la punta del medicamento antes de la conexi\u00f3n a la sonda<\/li><li>Conectar la jeringa a la sonda de administraci\u00f3n<\/li><li>Realizar la administraci\u00f3n<\/li><li>Observar que el volumen que queda en la punta jeringa es exactamente el mismo que el que se hab\u00eda observado antes de la administraci\u00f3n. Si la punta presenta la misma cantidad de l\u00edquido concluiremos que se ha reducido el riesgo de sobredosis.<\/li><\/ol>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/campusvygon.com\/es\/project\/simulacion-teorica-canula-extraccion\/\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"724\" src=\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/Paso-a-paso-canula-correcto_Mesa-de-trabajo-1-1024x724.jpg\" alt=\"\" class=\"wp-image-32680\" srcset=\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/Paso-a-paso-canula-correcto_Mesa-de-trabajo-1-980x693.jpg 980w, https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/Paso-a-paso-canula-correcto_Mesa-de-trabajo-1-480x340.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/a><\/figure><\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Sin embargo, <strong>a trav\u00e9s de las pruebas de laboratorio y de la puesta en pr\u00e1ctica del procedimiento se ha puesto de manifiesto que este tipo de situaciones solo se dan en el contexto te\u00f3rico y nunca en la realidad, <\/strong>incluso aplicando correctamente el protocolo de extracci\u00f3n con c\u00e1nula. Es decir, <strong>no es posible eliminar el riesgo de desplazamiento del volumen utilizando una c\u00e1nula de extracci\u00f3n.<\/strong><\/p>\n\n\n\n<p>Este hecho se debe, principalmente a <strong>el efecto de tensi\u00f3n superficial o la viscosidad del medicamento que produce variaciones en la dosis administrada<\/strong>, habi\u00e9ndose observado tanto peligro de sobredosificaci\u00f3n como de infradosificaci\u00f3n.<\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-embed aligncenter is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Simulaci\u00f3n te\u00f3rica: con c\u00e1nula de extracci\u00f3n en la carga de jeringa\" width=\"1080\" height=\"608\" src=\"https:\/\/www.youtube.com\/embed\/iUSqmfuhd1s?feature=oembed\"  allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>A continuaci\u00f3n, describimos las situaciones m\u00e1s habituales cuando se la c\u00e1nula de extracci\u00f3n para la carga de jeringas:<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>APLICACI\u00d3N INCORRECTA DE LA C\u00c1NULA:<\/strong><\/h4>\n\n\n\n<p>Este tipo de situaciones son habituales en el momento en el que no se sigue correctamente las indicaciones para cargar la jeringa al emplear accesorios como las c\u00e1nulas\/ pajitas.<\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/campusvygon.com\/es\/project\/aplicacion-incorrecta-canula-extraccion\/\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"724\" src=\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/Paso-a-paso-canula-incorrecto_Mesa-de-trabajo-1-1-1024x724.jpg\" alt=\"Paso a paso c\u00e1nula incorrecto_Mesa de trabajo 1\" class=\"wp-image-32682\" srcset=\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/Paso-a-paso-canula-incorrecto_Mesa-de-trabajo-1-1-980x693.jpg 980w, https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/Paso-a-paso-canula-incorrecto_Mesa-de-trabajo-1-1-480x340.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/a><\/figure><\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Se entiende como uso incorrecto de la c\u00e1nula cuando tras aspirar el f\u00e1rmaco\/la soluci\u00f3n con la finalidad de llenar la jeringa, <strong>desconectamos la c\u00e1nula antes de realizar el reajuste eliminando el aire <\/strong>que se ha producido durante el acto.<\/p>\n\n\n\n<p><strong>La aplicaci\u00f3n incorrecta del protocolo supone riesgo de sobredosis. <\/strong>Las pruebas en el laboratorio atestiguan que se puede producir un<strong> desplazamiento de la f\u00f3rmula de hasta 0.15 ml.<\/strong><\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-embed aligncenter is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Aplicaci\u00f3n incorrecta de la c\u00e1nula de extracci\u00f3n en la carga de jeringa\" width=\"1080\" height=\"608\" src=\"https:\/\/www.youtube.com\/embed\/GLn6eyRAQvw?feature=oembed\"  allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>APLICACI\u00d3N CORRECTA DE LA C\u00c1NULA CON RIESGO DE SOBREDOSIS<\/strong><\/h4>\n\n\n\n<p>Hablamos de riesgo de sobredosis cuando, siguiendo los pasos adecuados al cargar la jeringa con la c\u00e1nula (eliminaci\u00f3n del aire antes de la desconexi\u00f3n del dispositivo), <strong>al desconectarla, el l\u00edquido acumulado en esta se desplaza y queda atrapado en el espacio muerto del cono<\/strong> de la jeringa. Es entonces cuando, al conectar la jeringa a la sonda<strong>, el volumen de la f\u00f3rmula acumulada en la punta se desplazar\u00e1 hacia el tubo provocando una sobredosificaci\u00f3n<\/strong> en la administraci\u00f3n de hasta 0.15 ml.<\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/campusvygon.com\/es\/project\/canula-extraccion-sobredosis\/\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"724\" src=\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/Paso-a-paso-canula-sobredosis_Mesa-de-trabajo-1-1024x724.jpg\" alt=\"Paso a paso c\u00e1nula sobredosis_Mesa de trabajo 1\" class=\"wp-image-32686\" srcset=\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/Paso-a-paso-canula-sobredosis_Mesa-de-trabajo-1-980x693.jpg 980w, https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/Paso-a-paso-canula-sobredosis_Mesa-de-trabajo-1-480x340.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/a><\/figure><\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-embed aligncenter is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Aplicaci\u00f3n correcta de la c\u00e1nula de extracci\u00f3n en la carga de jeringa con riesgo de sobredosis\" width=\"1080\" height=\"608\" src=\"https:\/\/www.youtube.com\/embed\/mvm5ZQkJg4U?feature=oembed\"  allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>APLICACI\u00d3N CORRECTA DE LA C\u00c1NULA CON RIESGO INFRADOSIS<\/strong><\/h3>\n\n\n\n<p>Existe riesgo de no administrar la cantidad suficiente de f\u00f3rmula cuando, siguiendo estrictamente el protocolo de carga de jeringa mediante c\u00e1nula de extracci\u00f3n,&nbsp; se conecta la sonda a la jeringa para realiza la administraci\u00f3n y <strong>se observa que al desconectar ambos dispositivos parte de la f\u00f3rmula ha quedado pegada al cono de la jeringa y no ha sido completamente suministrada al paciente.<\/strong><\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/Paso-a-paso-canula-infrasobredosis-copia_Mesa-de-trabajo-1-1024x724.jpg\" alt=\"Paso a paso c\u00e1nula infrasobredosis - copia_Mesa de trabajo 1\" class=\"wp-image-32684\" width=\"821\" height=\"580\" \/><\/figure><\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-embed aligncenter is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Aplicaci\u00f3n correcta de la c\u00e1nula de extracci\u00f3n en la carga de jeringa con riesgo de infradosis\" width=\"1080\" height=\"608\" src=\"https:\/\/www.youtube.com\/embed\/Mk0B8WlHyjU?feature=oembed\"  allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Con este resumen, pues, podemos concluir que <strong>no existe situaci\u00f3n alguna en la que, <\/strong>a pesar de cargar la jeringa con una c\u00e1nula de extracci\u00f3n,<strong> se asegure la precisi\u00f3n de la dosis en la administraci\u00f3n de nutrici\u00f3n enteral con jeringa de conector ENFit.<\/strong><\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>\u00bfES RECOMENDABLE, POR TANTO, UTILIZAR C\u00c1NULAS DE EXTRACCI\u00d3N ?<\/strong><\/h3>\n\n\n\n<p>A pesar de que, como hemos vistos, las c\u00e1nulas de extracci\u00f3n no mejoran la precisi\u00f3n de la dosis a administrar al paciente neonatal, <strong>si es recomendable emplear estos dispositivos en el procedimiento de llenado de jeringas.<\/strong><\/p>\n\n\n\n<p>El empleo de c\u00e1nulas de extracci\u00f3n <strong>permite que el proceso sea m\u00e1s seguro durante la preparaci\u00f3n de al\u00edcuotas al reducir las posibilidades de contaminaci\u00f3n al cargar la f\u00f3rmula\/f\u00e1rmaco\/leche materna desde el envase o bote<\/strong> en el que se encuentra almacenado.&nbsp; Se recomienda escoger el tama\u00f1o de la c\u00e1nula seg\u00fan la viscosidad del f\u00e1rmaco que se administrar\u00e1: m\u00e1s peque\u00f1o para f\u00e1rmacos y f\u00f3rmulas de nutrici\u00f3n artificiales y de mayor di\u00e1metro para la leche materna.<\/p>\n\n\n\n<p>Ten en cuenta que, para asegurar una correcta precisi\u00f3n de la dosis a administrar, debes apostar por conectores seguros, ajustados al tama\u00f1o del neonato y exactos (con un volumen de desplazamiento menor a 0.03ml). &nbsp;<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-cover\" style=\"min-height:138px;aspect-ratio:unset;\"><span aria-hidden=\"true\" class=\"wp-block-cover__gradient-background has-background-dim\"><\/span><img loading=\"lazy\" decoding=\"async\" width=\"1238\" height=\"696\" class=\"wp-block-cover__image-background wp-image-32678\" alt=\"C\u00c1NULAS DE EXTRACCI\u00d3N: \u00bfSU USO AUMENTA LA PRECISI\u00d3N DE LA DOSIS DE LOS CONECTORES ENFit EN NEONATOS?\" src=\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/Captura-de-pantalla-2022-04-12-094533.png\" data-object-fit=\"cover\" srcset=\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/Captura-de-pantalla-2022-04-12-094533.png 1238w, https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/Captura-de-pantalla-2022-04-12-094533-980x551.png 980w, https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2022\/04\/Captura-de-pantalla-2022-04-12-094533-480x270.png 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1238px, 100vw\" \/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<p class=\"has-text-align-center has-medium-font-size\">TE PUEDE INTERESAR<\/p>\n\n\n\n<p class=\"has-text-align-center\"><a href=\"https:\/\/safe-enteral.com\/es\/\" target=\"_blank\" rel=\"noreferrer noopener\">Inicio &#8211; Safe Enteral (safe-enteral.com)<\/a><\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">BIBLIOGRAF\u00cdA<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li><em>The correct use of a draw-up device won\u2019t minimize the ENFit syringe inaccuracy<\/em>. (2016, 19 diciembre). [V\u00eddeo]. YouTube. <a href=\"https:\/\/www.youtube.com\/watch?v=hk4ycZz8mb0\">https:\/\/www.youtube.com\/watch?v=hk4ycZz8mb0<\/a><\/li><li><a href=\"https:\/\/www.scribbr.es\/taxonomy\/term\/814\">Center for Devices and Radiological Health<\/a>. (2021, 18 noviembre). <em>Potential for Medication Overdose with ENFit Low Dose Tip Syringe: FDA Safety Communication<\/em>. U.S. Food and Drug Administration. <a href=\"https:\/\/www.fda.gov\/medical-devices\/safety-communications\/potential-medication-overdose-enfit-low-dose-tip-syringe-fda-safety-communication\">https:\/\/www.fda.gov\/medical-devices\/safety-communications\/potential-medication-overdose-enfit-low-dose-tip-syringe-fda-safety-communication<\/a><\/li><li><em>ENFit Enteral Devices Are On Their Way. . .Important Safety Considerations For Hospitals<\/em>. (2015, 9 abril). Institute For Safe Medication Practices. <a href=\"https:\/\/www.ismp.org\/resources\/enfit-enteral-devices-are-their-wayimportant-safety-considerations-hospitals\">https:\/\/www.ismp.org\/resources\/enfit-enteral-devices-are-their-wayimportant-safety-considerations-hospitals<\/a><\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"<p>La llegada de los conectores ENFit, conectores \u201cseguros\u201d de nutrici\u00f3n enteral a las unidades de neonatolog\u00eda supuso el fin de los conocidos como \u201cerrores de conexi\u00f3n\u201d. Es decir, a partir de su incorporaci\u00f3n, ha resultado imposible conectar accidentalmente sistemas de administraci\u00f3n con objetivos diferentes (p. ej.: sistemas enterales con intravenosos).<\/p>\n","protected":false},"author":3,"featured_media":46497,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[286,259],"tags":[87,92],"class_list":["post-32675","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-neonatologia","category-nutricion-enteral","tag-nutricion-enteral","tag-nutricion-neonatal"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u00bfAumenta la precisi\u00f3n de la dosis usar c\u00e1nulas de extracci\u00f3n en NE neonatal?<\/title>\n<meta name=\"description\" content=\"El uso de ENfit en la NE neonatal supone el desplazamiento de un volumen muerto de 0.148 ml. \u00bfUsar c\u00e1nulas de extracci\u00f3n aumenta la precisi\u00f3n?\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/campusvygon.com\/es\/canulas-extraccion-precision-enfit-neonatos\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u00bfAumenta la precisi\u00f3n de la dosis usar c\u00e1nulas de extracci\u00f3n en NE neonatal?\" \/>\n<meta property=\"og:description\" content=\"El uso de ENfit en la NE neonatal supone el desplazamiento de un volumen muerto de 0.148 ml. \u00bfUsar c\u00e1nulas de extracci\u00f3n aumenta la precisi\u00f3n?\" \/>\n<meta property=\"og:url\" content=\"https:\/\/campusvygon.com\/es\/canulas-extraccion-precision-enfit-neonatos\/\" \/>\n<meta property=\"og:site_name\" content=\"Campus Vygon Espa\u00f1a\" \/>\n<meta property=\"article:published_time\" content=\"2022-04-13T05:55:35+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-21T11:16:23+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2025\/07\/Portada-Canulas-de-extraccion-scaled.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1707\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Paula Navarro\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Paula Navarro\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/canulas-extraccion-precision-enfit-neonatos\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/canulas-extraccion-precision-enfit-neonatos\\\/\"},\"author\":{\"name\":\"Paula Navarro\",\"@id\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/#\\\/schema\\\/person\\\/d2318c54d1af489bff83c9142f67bf82\"},\"headline\":\"C\u00c1NULAS DE EXTRACCI\u00d3N: \u00bfSU USO AUMENTA LA PRECISI\u00d3N DE LA DOSIS DE LOS CONECTORES ENFit EN NEONATOS?\",\"datePublished\":\"2022-04-13T05:55:35+00:00\",\"dateModified\":\"2025-07-21T11:16:23+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/canulas-extraccion-precision-enfit-neonatos\\\/\"},\"wordCount\":1333,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/canulas-extraccion-precision-enfit-neonatos\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2025\\\/07\\\/Portada-Canulas-de-extraccion-scaled.jpeg\",\"keywords\":[\"nutrici\u00f3n enteral\",\"nutrici\u00f3n neonatal\"],\"articleSection\":[\"Neonatolog\u00eda\",\"Nutrici\u00f3n Enteral\"],\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/campusvygon.com\\\/es\\\/canulas-extraccion-precision-enfit-neonatos\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/canulas-extraccion-precision-enfit-neonatos\\\/\",\"url\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/canulas-extraccion-precision-enfit-neonatos\\\/\",\"name\":\"\u00bfAumenta la precisi\u00f3n de la dosis usar c\u00e1nulas de extracci\u00f3n en NE neonatal?\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/canulas-extraccion-precision-enfit-neonatos\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/canulas-extraccion-precision-enfit-neonatos\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2025\\\/07\\\/Portada-Canulas-de-extraccion-scaled.jpeg\",\"datePublished\":\"2022-04-13T05:55:35+00:00\",\"dateModified\":\"2025-07-21T11:16:23+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/#\\\/schema\\\/person\\\/d2318c54d1af489bff83c9142f67bf82\"},\"description\":\"El uso de ENfit en la NE neonatal supone el desplazamiento de un volumen muerto de 0.148 ml. \u00bfUsar c\u00e1nulas de extracci\u00f3n aumenta la precisi\u00f3n?\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/canulas-extraccion-precision-enfit-neonatos\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/campusvygon.com\\\/es\\\/canulas-extraccion-precision-enfit-neonatos\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/canulas-extraccion-precision-enfit-neonatos\\\/#primaryimage\",\"url\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2025\\\/07\\\/Portada-Canulas-de-extraccion-scaled.jpeg\",\"contentUrl\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2025\\\/07\\\/Portada-Canulas-de-extraccion-scaled.jpeg\",\"width\":2560,\"height\":1707,\"caption\":\"c\u00e1nulas de extracci\u00f3n\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/canulas-extraccion-precision-enfit-neonatos\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"C\u00c1NULAS DE EXTRACCI\u00d3N: \u00bfSU USO AUMENTA LA PRECISI\u00d3N DE LA DOSIS DE LOS CONECTORES ENFit EN NEONATOS?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/\",\"name\":\"Campus Vygon Espa\u00f1a\",\"description\":\"Un espacio para aprender sobre procedimientos y t\u00e9cnicas sanitarias de la mano de profesionales de referencia.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/#\\\/schema\\\/person\\\/d2318c54d1af489bff83c9142f67bf82\",\"name\":\"Paula Navarro\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/wp-content\\\/plugins\\\/wp-user-avatar\\\/deprecated\\\/wp-user-avatar\\\/images\\\/wpua-96x96.png\",\"url\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/wp-content\\\/plugins\\\/wp-user-avatar\\\/deprecated\\\/wp-user-avatar\\\/images\\\/wpua-96x96.png\",\"contentUrl\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/wp-content\\\/plugins\\\/wp-user-avatar\\\/deprecated\\\/wp-user-avatar\\\/images\\\/wpua-96x96.png\",\"caption\":\"Paula Navarro\"},\"description\":\"Responsable de contenidos de las unidades de negocio Obstetricia, Neonatolog\u00eda y Nutrici\u00f3n enteral y Terapias Intravasculares en Vygon Espa\u00f1a. \u2022 EXPERIENCIA Soy una joven periodista a la que le apasiona todas las posibilidades que le ofrece su oficio. Disfruto de la comunicaci\u00f3n corporativa, ya que me permite crecer profesional y personalmente, adquiriendo conocimientos y t\u00e9cnicas en el mundo de sanitario en el \u00e1mbito de la comunicaci\u00f3n y el marketing. Adem\u00e1s, combino esta parte m\u00e1s t\u00e9cnica con mi desempe\u00f1o en los medios de comunicaci\u00f3n en un programa de la radio local valenciana. \u2022 PUEDO AYUDARTE EN\u2026 Mi trabajo se basa en una apuesta clara de Vygon por la formaci\u00f3n digital y el aprendizaje continuo. Puedes contactarme si buscas material digital sobre alg\u00fan procedimiento o t\u00e9cnica habitual en los servicios de Neonatolog\u00eda, Obstetricia, Nutrici\u00f3n Enteral y Terapias Intravasculares.\",\"sameAs\":[\"https:\\\/\\\/www.vygon.es\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/paula-navarro-faus-708a7b13b\\\/\"],\"url\":\"https:\\\/\\\/campusvygon.com\\\/es\\\/author\\\/pnavarro\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u00bfAumenta la precisi\u00f3n de la dosis usar c\u00e1nulas de extracci\u00f3n en NE neonatal?","description":"El uso de ENfit en la NE neonatal supone el desplazamiento de un volumen muerto de 0.148 ml. \u00bfUsar c\u00e1nulas de extracci\u00f3n aumenta la precisi\u00f3n?","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/campusvygon.com\/es\/canulas-extraccion-precision-enfit-neonatos\/","og_locale":"es_ES","og_type":"article","og_title":"\u00bfAumenta la precisi\u00f3n de la dosis usar c\u00e1nulas de extracci\u00f3n en NE neonatal?","og_description":"El uso de ENfit en la NE neonatal supone el desplazamiento de un volumen muerto de 0.148 ml. \u00bfUsar c\u00e1nulas de extracci\u00f3n aumenta la precisi\u00f3n?","og_url":"https:\/\/campusvygon.com\/es\/canulas-extraccion-precision-enfit-neonatos\/","og_site_name":"Campus Vygon Espa\u00f1a","article_published_time":"2022-04-13T05:55:35+00:00","article_modified_time":"2025-07-21T11:16:23+00:00","og_image":[{"width":2560,"height":1707,"url":"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2025\/07\/Portada-Canulas-de-extraccion-scaled.jpeg","type":"image\/jpeg"}],"author":"Paula Navarro","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Paula Navarro","Tiempo de lectura":"7 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/campusvygon.com\/es\/canulas-extraccion-precision-enfit-neonatos\/#article","isPartOf":{"@id":"https:\/\/campusvygon.com\/es\/canulas-extraccion-precision-enfit-neonatos\/"},"author":{"name":"Paula Navarro","@id":"https:\/\/campusvygon.com\/es\/#\/schema\/person\/d2318c54d1af489bff83c9142f67bf82"},"headline":"C\u00c1NULAS DE EXTRACCI\u00d3N: \u00bfSU USO AUMENTA LA PRECISI\u00d3N DE LA DOSIS DE LOS CONECTORES ENFit EN NEONATOS?","datePublished":"2022-04-13T05:55:35+00:00","dateModified":"2025-07-21T11:16:23+00:00","mainEntityOfPage":{"@id":"https:\/\/campusvygon.com\/es\/canulas-extraccion-precision-enfit-neonatos\/"},"wordCount":1333,"commentCount":0,"image":{"@id":"https:\/\/campusvygon.com\/es\/canulas-extraccion-precision-enfit-neonatos\/#primaryimage"},"thumbnailUrl":"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2025\/07\/Portada-Canulas-de-extraccion-scaled.jpeg","keywords":["nutrici\u00f3n enteral","nutrici\u00f3n neonatal"],"articleSection":["Neonatolog\u00eda","Nutrici\u00f3n Enteral"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/campusvygon.com\/es\/canulas-extraccion-precision-enfit-neonatos\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/campusvygon.com\/es\/canulas-extraccion-precision-enfit-neonatos\/","url":"https:\/\/campusvygon.com\/es\/canulas-extraccion-precision-enfit-neonatos\/","name":"\u00bfAumenta la precisi\u00f3n de la dosis usar c\u00e1nulas de extracci\u00f3n en NE neonatal?","isPartOf":{"@id":"https:\/\/campusvygon.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/campusvygon.com\/es\/canulas-extraccion-precision-enfit-neonatos\/#primaryimage"},"image":{"@id":"https:\/\/campusvygon.com\/es\/canulas-extraccion-precision-enfit-neonatos\/#primaryimage"},"thumbnailUrl":"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2025\/07\/Portada-Canulas-de-extraccion-scaled.jpeg","datePublished":"2022-04-13T05:55:35+00:00","dateModified":"2025-07-21T11:16:23+00:00","author":{"@id":"https:\/\/campusvygon.com\/es\/#\/schema\/person\/d2318c54d1af489bff83c9142f67bf82"},"description":"El uso de ENfit en la NE neonatal supone el desplazamiento de un volumen muerto de 0.148 ml. \u00bfUsar c\u00e1nulas de extracci\u00f3n aumenta la precisi\u00f3n?","breadcrumb":{"@id":"https:\/\/campusvygon.com\/es\/canulas-extraccion-precision-enfit-neonatos\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/campusvygon.com\/es\/canulas-extraccion-precision-enfit-neonatos\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/campusvygon.com\/es\/canulas-extraccion-precision-enfit-neonatos\/#primaryimage","url":"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2025\/07\/Portada-Canulas-de-extraccion-scaled.jpeg","contentUrl":"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2025\/07\/Portada-Canulas-de-extraccion-scaled.jpeg","width":2560,"height":1707,"caption":"c\u00e1nulas de extracci\u00f3n"},{"@type":"BreadcrumbList","@id":"https:\/\/campusvygon.com\/es\/canulas-extraccion-precision-enfit-neonatos\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/campusvygon.com\/es\/"},{"@type":"ListItem","position":2,"name":"C\u00c1NULAS DE EXTRACCI\u00d3N: \u00bfSU USO AUMENTA LA PRECISI\u00d3N DE LA DOSIS DE LOS CONECTORES ENFit EN NEONATOS?"}]},{"@type":"WebSite","@id":"https:\/\/campusvygon.com\/es\/#website","url":"https:\/\/campusvygon.com\/es\/","name":"Campus Vygon Espa\u00f1a","description":"Un espacio para aprender sobre procedimientos y t\u00e9cnicas sanitarias de la mano de profesionales de referencia.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/campusvygon.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/campusvygon.com\/es\/#\/schema\/person\/d2318c54d1af489bff83c9142f67bf82","name":"Paula Navarro","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/campusvygon.com\/es\/wp-content\/plugins\/wp-user-avatar\/deprecated\/wp-user-avatar\/images\/wpua-96x96.png","url":"https:\/\/campusvygon.com\/es\/wp-content\/plugins\/wp-user-avatar\/deprecated\/wp-user-avatar\/images\/wpua-96x96.png","contentUrl":"https:\/\/campusvygon.com\/es\/wp-content\/plugins\/wp-user-avatar\/deprecated\/wp-user-avatar\/images\/wpua-96x96.png","caption":"Paula Navarro"},"description":"Responsable de contenidos de las unidades de negocio Obstetricia, Neonatolog\u00eda y Nutrici\u00f3n enteral y Terapias Intravasculares en Vygon Espa\u00f1a. \u2022 EXPERIENCIA Soy una joven periodista a la que le apasiona todas las posibilidades que le ofrece su oficio. Disfruto de la comunicaci\u00f3n corporativa, ya que me permite crecer profesional y personalmente, adquiriendo conocimientos y t\u00e9cnicas en el mundo de sanitario en el \u00e1mbito de la comunicaci\u00f3n y el marketing. Adem\u00e1s, combino esta parte m\u00e1s t\u00e9cnica con mi desempe\u00f1o en los medios de comunicaci\u00f3n en un programa de la radio local valenciana. \u2022 PUEDO AYUDARTE EN\u2026 Mi trabajo se basa en una apuesta clara de Vygon por la formaci\u00f3n digital y el aprendizaje continuo. Puedes contactarme si buscas material digital sobre alg\u00fan procedimiento o t\u00e9cnica habitual en los servicios de Neonatolog\u00eda, Obstetricia, Nutrici\u00f3n Enteral y Terapias Intravasculares.","sameAs":["https:\/\/www.vygon.es\/","https:\/\/www.linkedin.com\/in\/paula-navarro-faus-708a7b13b\/"],"url":"https:\/\/campusvygon.com\/es\/author\/pnavarro\/"}]}},"_links":{"self":[{"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/posts\/32675","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/comments?post=32675"}],"version-history":[{"count":7,"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/posts\/32675\/revisions"}],"predecessor-version":[{"id":46500,"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/posts\/32675\/revisions\/46500"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/media\/46497"}],"wp:attachment":[{"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/media?parent=32675"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/categories?post=32675"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/tags?post=32675"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}