{"id":5908,"date":"2019-05-10T13:16:34","date_gmt":"2019-05-10T11:16:34","guid":{"rendered":"http:\/\/campusvygon.com\/es\/?p=5908"},"modified":"2025-09-27T21:35:38","modified_gmt":"2025-09-27T19:35:38","slug":"enfit-incompatible-seguridad-neonatal-2","status":"publish","type":"post","link":"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/","title":{"rendered":"ENFit un sistema incompatible con la seguridad neonatal II"},"content":{"rendered":"\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-font-size has-small-font-size\"><a class=\"wp-block-button__link\" href=\"http:\/\/campusvygon.com\/es\/project\/whitepaper-enfit-un-sistema-incompatible-con-la-seguridad-neonatal\/\" target=\"_blank\" rel=\"noreferrer noopener\"><mark class=\"has-inline-color has-white-color\">Descarga en pdf<\/mark><\/a><\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator\" \/>\n\n\n\n<p>ENFit ha supuesto una gran soluci\u00f3n para acabar con las equivocaciones en los errores de conexi\u00f3n entre sondas, cat\u00e9teres y jeringas. Sin embargo, como ya hemos visto en la primera parte de la serie <a href=\"http:\/\/campusvygon.com\/es\/enfit-no-seguro-neonatos\/\">ENFit un sistema incompatible con la seguridad neonatal<\/a>, ha planteado nuevos retos y preocupaciones entre los profesionales sanitarios.<\/p>\n\n\n\n<div style=\"height:51px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/formacion.campusvygon.com\/es\/cursos\/curso-pendiente-de-acreditacion---nutricion-enteral-segura-en-neonatos-86?edicion=101&amp;tab=info\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"512\" src=\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2021\/12\/twitter-facebook-2.jpg\" alt=\"Curso: Nutrici\u00f3n enteral seguro en neonatos\" class=\"wp-image-31559\" srcset=\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2021\/12\/twitter-facebook-2.jpg 1024w, https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2021\/12\/twitter-facebook-2-980x490.jpg 980w, https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2021\/12\/twitter-facebook-2-480x240.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" \/><\/a><\/figure>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Las inquietudes sobre los posibles riesgos de sobredosis en neonatos que ENFit puede ocasionar est\u00e1n motivados por el cambio de orientaci\u00f3n en el nuevo dispositivo de nutrici\u00f3n enteral). Mientras que la extremidad de la jeringa del sistema est\u00e1ndar (macho-hembra) deja poco espacio para una sobredosis, la extremidad de la jeringa del sistema de ENFit (hembra-macho) tiene un volumen muerto muy superior, incrementando el riesgo de sobredosis.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>La limpieza del cono: una puerta abierta a la sobredosis<\/strong><\/h4>\n\n\n\n<p>La inversi\u00f3n de la conexi\u00f3n ENFit complica el procedimiento de limpieza del cono de la jeringa ENFit. Este hecho aumenta la posibilidad de que residuos de f\u00e1rmacos orales u otras sustancias queden escondidos en esta parte del dispositivo, lo que aumenta la cantidad de dosis que se desplaza hacia la sonda y que percibe el paciente.<\/p>\n\n\n\n<p>Si no se limpia correctamente el cono, el prematuro podr\u00eda recibir hasta un 30% m\u00e1s de la medicaci\u00f3n y el paciente podr\u00eda sufrir reacciones adversas al f\u00e1rmaco administrado.<\/p>\n\n\n<p><iframe loading=\"lazy\" title=\"\u00bfEs seguro usar ENfit en la nutrici\u00f3n neonatal?\" width=\"1080\" height=\"608\" src=\"https:\/\/www.youtube.com\/embed\/xRy2aouork0?start=4&#038;feature=oembed\"  allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Riesgo de mala praxis<\/strong><\/h4>\n\n\n\n<p>Las dificultades para eliminar el sobrante de la administraci\u00f3n que queda almacenada en el cono de la jeringa y, as\u00ed, ajustar la precisi\u00f3n de la dosis plantea obst\u00e1culos en el flujo de trabajo. No existe un protocolo preciso de actuaci\u00f3n para corregir la complejidad que el dise\u00f1o ENFit requiere para suministrar la dosis con precisi\u00f3n. As\u00ed, lo denunci\u00f3 <a href=\"https:\/\/allianceforpatientaccess.org\/tubing-mix-ups-pose-new-dangers-for-infants\/\">El Institute for Patient Accent.<\/a><\/p>\n\n\n\n<p>Entre los profesionales sanitarios (m\u00e9dicos, enfermeras, farmac\u00e9uticos) existe una gran preocupaci\u00f3n sobre la falta de un nuevo procedimiento y las consecuencias a largo plazo que pueden desarrollar sus pacientes debido a una mala praxis por su actividad.<\/p>\n\n\n<p><iframe loading=\"lazy\" title=\"Seguridad en las UCIN. ENFiT: \u00bfnuevas conexiones, nuevos problemas?\" width=\"1080\" height=\"608\" src=\"https:\/\/www.youtube.com\/embed\/HYaspUKBikI?feature=oembed\"  allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/p>\n\n\n\n<p>Por su parte, el equipo farmac\u00e9utico, como denuncia la farmac\u00e9utica Keliana O\u2019Mara en el v\u00eddeo publicado por la Coalici\u00f3n Nacional de la Salud Infantil de los Estados Unidos, asume una nueva carga en el flujo del trabajo al disponer de medicaci\u00f3n en jeringas orales y enterales, y debe asegurarse de que la medicaci\u00f3n no se encuentre en un lugar equivocado cuando la jeringa se tape.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>La contaminaci\u00f3n bacteriana aumenta con ENFit<\/strong><\/h4>\n\n\n\n<p><a href=\"http:\/\/www.infanthealth.org\/\">La Coalici\u00f3n Nacional de Salud Infantil de Estados Unidos<\/a><u> (NCFIH)<\/u> advierte que el dise\u00f1o del cono tambi\u00e9n aumenta el riesgo de infecci\u00f3n si queda leche materna residual o leche preparada en el dep\u00f3sito. Las sondas de nutrici\u00f3n enteral en pacientes ingresados en la UCIN se utilizan durante largos periodos de tiempo. Por lo tanto, el riesgo de contaminaci\u00f3n bacteriana del dispositivo aumenta con el dise\u00f1o de ENFit debido a la dificultad planteada a la hora de limpiar el conector de la jeringa de este dise\u00f1o.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignleft\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"206\" src=\"http:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2019\/05\/Nutrifit_Nutrisafe2-300x206.png\" alt=\"Conectores enfit\" class=\"wp-image-5902\" srcset=\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2019\/05\/Nutrifit_Nutrisafe2-300x206.png 300w, https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2019\/05\/Nutrifit_Nutrisafe2-768x527.png 768w, https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2019\/05\/Nutrifit_Nutrisafe2-1024x703.png 1024w, https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2019\/05\/Nutrifit_Nutrisafe2.png 1200w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/figure><\/div>\n\n\n\n<p>Adem\u00e1s de la gran problem\u00e1tica de la sobredosis por el dise\u00f1o del cono, ENFit presenta otro problema que afecta a los pacientes m\u00e1s peque\u00f1os. El tama\u00f1o del nuevo dispositivo enteral ENFit es muy superior a los conectores actuales existentes en el mercado. Dado su gran tama\u00f1o, desconectar jeringa y sonda se complica al tener residuos de leche o medicamentos orales que hace que la jeringa se adhiera, se pegue m\u00e1s, a la sonda. Tambi\u00e9n, en prematuros, una conexi\u00f3n grande y pesada&nbsp; conlleva riesgos por lesiones cut\u00e1neas o desplazamiento inoportuna de la sonda.<\/p>\n\n\n\n<p>Por estos motivos, la <a href=\"http:\/\/www.safe-enteral.com\/es\/enfit\/?cn-reloaded=1\">Sociedad Francesa de Neonatolog\u00eda recomienda un sistema enteral<b>:<\/b><\/a><\/p>\n\n\n\n<p><a href=\"http:\/\/www.safe-enteral.com\/es\/nutrisafe2-neonates\/\"><strong>Seguro<\/strong>:<\/a><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>&nbsp;Incompatible con los conectores Luer y otros conectores de di\u00e1metro peque\u00f1o utilizados en otras aplicaciones (p. ej., i.v.)<\/li><li>Permite una conexi\u00f3n fiable entre los componentes sin fugas ni fisuras<\/li><\/ul>\n\n\n\n<p><a href=\"http:\/\/www.safe-enteral.com\/es\/nutrisafe2-neonates\/\"><strong>Exacto<\/strong>:<\/a><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Espacio muerto interno inferior a 0,1 ml<\/li><li>Generaci\u00f3n de un desplazamiento del fluido inferior a 0,05 ml durante la conexi\u00f3n<\/li><\/ul>\n\n\n\n<p><a href=\"http:\/\/www.safe-enteral.com\/es\/nutrisafe2-neonates\/\"><strong>Tama\u00f1o adaptado a prematuros<\/strong>:<\/a><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Con los conectores m\u00e1s peque\u00f1os posibles<\/li><li>Con los conectores m\u00e1s ligeros posible<\/li><\/ul>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Seguridad neonatal a debate<\/strong><\/h4>\n\n\n\n<p>Los diferentes riesgos que conlleva el uso de ENFit en neonatos han impulsado a algunas organizaciones a mostrarse contrarias al uso de ENFit en estos pacientes de alto riesgo.<\/p>\n\n\n\n<p>El grupo de trabajo (CSA Z298) del <a href=\"https:\/\/www.csagroup.org\/\">Comit\u00e9 de Estandarizaci\u00f3n Canadiense<\/a> ha decidido no apoyar la norma ISO 80396-3 y no recomendar el uso de estos conectores argumentando \u201cgraves deficiencias en el proyecto\u201d. Uno de los motivos t\u00e9cnicos de que no lo apoye es la inexactitud de las dosis del sistema ENFit <sup>(2)<\/sup>.<\/p>\n\n\n\n<p>La NCFIH entiende la urgencia de una norma &nbsp;como la ISO 80369-3, es decir, defiende la necesidad de crear un dise\u00f1o de conector oral\/enteral que prevenga conexiones defectuosas y mejore la seguridad del paciente. Sin embargo, asegura, que el dise\u00f1o de ENFit crea nuevos riesgos, ya que aumenta la dosis del f\u00e1rmaco oral administrado y dificulta el desarrollo de la actividad de los profesionales sanitarios.<\/p>\n\n\n\n<p>Adem\u00e1s, desde la Coalici\u00f3n, han luchado por mejorar el nuevo dise\u00f1o con el objetivo de que se ajuste a las directrices de prevenci\u00f3n de errores de medicaci\u00f3n del Consejo Coordinaci\u00f3n de Informaci\u00f3n y Prevenci\u00f3n e Errores M\u00e9dicos de los Estados Unidos. Por ello, <a href=\"http:\/\/www.safe-enteral.com\/wp-content\/uploads\/sites\/7\/2019\/01\/08-es-10.4.17-jc-ncfih-tubing-carta.pdf\">envi\u00f3 una carta a The Joint Commission <\/a><u>,<\/u>ente encargado de verla por la seguridad del paciente en las organizaciones sanitarias, para que considerase otros dise\u00f1os de fabricantes alternativos.<\/p>\n\n\n\n<p><a href=\"http:\/\/www.safe-enteral.com\/wp-content\/uploads\/sites\/7\/2019\/01\/10-ncfih-11.10.17-respuesta.pdf\">&nbsp;The Joint Commission <\/a>&nbsp;a pesar de reconocer las limitaciones por la complejidad del sistema del dise\u00f1o de ISO 80369 no es firme en su posicionamiento y deja a elecci\u00f3n de los paciente y m\u00e9dicos la selecci\u00f3n de dispositivos espec\u00edficos y el uso de sus productos.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>En busca de una soluci\u00f3n <\/strong><\/h4>\n\n\n\n<p>El debate sobre la seguridad de la conexi\u00f3n ENFit en los m\u00e1s peque\u00f1os ha suscitado la b\u00fasqueda de alternativas que si sean eficientes para el cuidado y alimentaci\u00f3n enteral de los neonatos. Sin embargo, a\u00fan hoy algunas de estas posibles soluciones, plantean dudas al respecto sobre su efectividad.<\/p>\n\n\n\n<p>Continuar\u00e1.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Serie de art\u00edculos sobre nutrici\u00f3n enteral:<\/h4>\n\n\n\n<ul class=\"wp-block-list\"><li><a href=\"http:\/\/campusvygon.com\/es\/iso-803693-enfit-nutricion-enteral\/\">Nutrici\u00f3n Enteral: De la preocupaci\u00f3n a la norma ISO 80369-3, ENFIT<\/a><\/li><li><a href=\"http:\/\/campusvygon.com\/es\/enfit-no-seguro-neonatos\/\">ENFit un sistema incompatible con la seguridad neonatal<\/a><\/li><li><a href=\"http:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/\">ENFit un sistema incompatible con la seguridad neonatal II<\/a><\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Bibliograf\u00eda:<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>Soci\u00e9t\u00e9 Fran\u00e7aise de N\u00e9onatologie. (2019). Retrieved from&nbsp;<a href=\"http:\/\/www.safe-enteral.com\/wp-content\/uploads\/sites\/7\/2017\/01\/newsletter_sfn_mars2016_fr.pdf\">http:\/\/www.safe-enteral.com\/wp-content\/uploads\/sites\/7\/2017\/01\/newsletter_sfn_mars2016_fr.pdf<\/a><\/li><li>Necesidades &#8211; Safe Enteral. (2019). Retrieved from <a href=\"http:\/\/www.safe-enteral.com\/es\/neonatology-needs\/\">http:\/\/www.safe-enteral.com\/es\/neonatology-needs\/<\/a><\/li><li>ISO 80369 Content. (2019). Retrieved from <a href=\"http:\/\/www.safe-enteral.com\/es\/content\/\">http:\/\/www.safe-enteral.com\/es\/content\/<\/a><\/li><li>David Young. <span lang=\"EN-US\">Z289 and SMC\/ISO\/TC 210<\/span><span lang=\"EN-US\">&nbsp;<\/span><\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u00bfTe interesa este tema?<\/h3>\n\n\n\n<p>Si quieres saber m\u00e1s acerca de ENFit y la seguridad de los neoantatos, rellena el formulario con tus datos y dudas e intentaremos ayudarte a resolverlas.<br>Tranquil@, esto NO es una lista de SPAM.<br>SOLO utilizaremos tus datos para responder a las preguntas que nos hagas.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-font-size has-small-font-size\"><a class=\"wp-block-button__link\" href=\"http:\/\/campusvygon.com\/es\/contact\/\" target=\"_blank\" rel=\"noreferrer noopener\"><mark class=\"has-inline-color has-white-color\">M\u00e1s de informaci\u00f3n<\/mark><\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>ENFit ha supuesto una gran soluci\u00f3n para acabar con las equivocaciones en los errores de conexi\u00f3n entre sondas, cat\u00e9teres y jeringas. Sin embargo, como ya hemos visto en la primera parte de la serie ENFit un sistema incompatible con la seguridad neonatal, ha planteado nuevos retos y preocupaciones entre los profesionales sanitarios. Las inquietudes sobre [&hellip;]<\/p>\n","protected":false},"author":33,"featured_media":47839,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[259],"tags":[86,91,87,107],"class_list":["post-5908","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nutricion-enteral","tag-enfit","tag-neonatologia","tag-nutricion-enteral","tag-prematuros"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ENFit un sistema incompatible con la seguridad neonatal II<\/title>\n<meta name=\"description\" content=\"Riesgo de sobredosis, contaminaci\u00f3n bacteriana... Haz clic y conoce los argumentos por los que ENFit es un sistema incompatible con la seguridad neonatal\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ENFit un sistema incompatible con la seguridad neonatal II\" \/>\n<meta property=\"og:description\" content=\"Riesgo de sobredosis, contaminaci\u00f3n bacteriana... Haz clic y conoce los argumentos por los que ENFit es un sistema incompatible con la seguridad neonatal\" \/>\n<meta property=\"og:url\" content=\"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/\" \/>\n<meta property=\"og:site_name\" content=\"Campus Vygon Espa\u00f1a\" \/>\n<meta property=\"article:published_time\" content=\"2019-05-10T11:16:34+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-27T19:35:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2025\/09\/Portada-ENFit-incompatible-scaled.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1700\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Hiba Malek\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Hiba Malek\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/\"},\"author\":{\"name\":\"Hiba Malek\",\"@id\":\"https:\/\/campusvygon.com\/es\/#\/schema\/person\/00232c1410da1c96291ba4ad132d92a3\"},\"headline\":\"ENFit un sistema incompatible con la seguridad neonatal II\",\"datePublished\":\"2019-05-10T11:16:34+00:00\",\"dateModified\":\"2025-09-27T19:35:38+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/\"},\"wordCount\":1237,\"commentCount\":10,\"image\":{\"@id\":\"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2025\/09\/Portada-ENFit-incompatible-scaled.jpeg\",\"keywords\":[\"ENfit\",\"neonatolog\u00eda\",\"nutrici\u00f3n enteral\",\"prematuros\"],\"articleSection\":[\"Nutrici\u00f3n Enteral\"],\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/\",\"url\":\"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/\",\"name\":\"ENFit un sistema incompatible con la seguridad neonatal II\",\"isPartOf\":{\"@id\":\"https:\/\/campusvygon.com\/es\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2025\/09\/Portada-ENFit-incompatible-scaled.jpeg\",\"datePublished\":\"2019-05-10T11:16:34+00:00\",\"dateModified\":\"2025-09-27T19:35:38+00:00\",\"author\":{\"@id\":\"https:\/\/campusvygon.com\/es\/#\/schema\/person\/00232c1410da1c96291ba4ad132d92a3\"},\"description\":\"Riesgo de sobredosis, contaminaci\u00f3n bacteriana... Haz clic y conoce los argumentos por los que ENFit es un sistema incompatible con la seguridad neonatal\",\"breadcrumb\":{\"@id\":\"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/#primaryimage\",\"url\":\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2025\/09\/Portada-ENFit-incompatible-scaled.jpeg\",\"contentUrl\":\"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2025\/09\/Portada-ENFit-incompatible-scaled.jpeg\",\"width\":2560,\"height\":1700},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\/\/campusvygon.com\/es\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ENFit un sistema incompatible con la seguridad neonatal II\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/campusvygon.com\/es\/#website\",\"url\":\"https:\/\/campusvygon.com\/es\/\",\"name\":\"Campus Vygon Espa\u00f1a\",\"description\":\"Un espacio para aprender sobre procedimientos y t\u00e9cnicas sanitarias de la mano de profesionales de referencia.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/campusvygon.com\/es\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/campusvygon.com\/es\/#\/schema\/person\/00232c1410da1c96291ba4ad132d92a3\",\"name\":\"Hiba Malek\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/campusvygon.com\/es\/wp-content\/plugins\/wp-user-avatar\/deprecated\/wp-user-avatar\/images\/wpua-96x96.png\",\"url\":\"https:\/\/campusvygon.com\/es\/wp-content\/plugins\/wp-user-avatar\/deprecated\/wp-user-avatar\/images\/wpua-96x96.png\",\"contentUrl\":\"https:\/\/campusvygon.com\/es\/wp-content\/plugins\/wp-user-avatar\/deprecated\/wp-user-avatar\/images\/wpua-96x96.png\",\"caption\":\"Hiba Malek\"},\"description\":\"Responsable de las Unidades de Negocio de Terapias Intravasculares - Obstetricia, Neonatolog\u00eda y Nutrici\u00f3n Enteral - Vygon Espa\u00f1a\",\"sameAs\":[\"https:\/\/www.vygon.es\/\",\"https:\/\/www.linkedin.com\/in\/hiba-malek-b7b4655a\/\"],\"url\":\"https:\/\/campusvygon.com\/es\/author\/hmalek\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ENFit un sistema incompatible con la seguridad neonatal II","description":"Riesgo de sobredosis, contaminaci\u00f3n bacteriana... Haz clic y conoce los argumentos por los que ENFit es un sistema incompatible con la seguridad neonatal","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/","og_locale":"es_ES","og_type":"article","og_title":"ENFit un sistema incompatible con la seguridad neonatal II","og_description":"Riesgo de sobredosis, contaminaci\u00f3n bacteriana... Haz clic y conoce los argumentos por los que ENFit es un sistema incompatible con la seguridad neonatal","og_url":"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/","og_site_name":"Campus Vygon Espa\u00f1a","article_published_time":"2019-05-10T11:16:34+00:00","article_modified_time":"2025-09-27T19:35:38+00:00","og_image":[{"width":2560,"height":1700,"url":"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2025\/09\/Portada-ENFit-incompatible-scaled.jpeg","type":"image\/jpeg"}],"author":"Hiba Malek","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Hiba Malek","Tiempo de lectura":"6 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/#article","isPartOf":{"@id":"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/"},"author":{"name":"Hiba Malek","@id":"https:\/\/campusvygon.com\/es\/#\/schema\/person\/00232c1410da1c96291ba4ad132d92a3"},"headline":"ENFit un sistema incompatible con la seguridad neonatal II","datePublished":"2019-05-10T11:16:34+00:00","dateModified":"2025-09-27T19:35:38+00:00","mainEntityOfPage":{"@id":"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/"},"wordCount":1237,"commentCount":10,"image":{"@id":"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/#primaryimage"},"thumbnailUrl":"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2025\/09\/Portada-ENFit-incompatible-scaled.jpeg","keywords":["ENfit","neonatolog\u00eda","nutrici\u00f3n enteral","prematuros"],"articleSection":["Nutrici\u00f3n Enteral"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/","url":"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/","name":"ENFit un sistema incompatible con la seguridad neonatal II","isPartOf":{"@id":"https:\/\/campusvygon.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/#primaryimage"},"image":{"@id":"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/#primaryimage"},"thumbnailUrl":"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2025\/09\/Portada-ENFit-incompatible-scaled.jpeg","datePublished":"2019-05-10T11:16:34+00:00","dateModified":"2025-09-27T19:35:38+00:00","author":{"@id":"https:\/\/campusvygon.com\/es\/#\/schema\/person\/00232c1410da1c96291ba4ad132d92a3"},"description":"Riesgo de sobredosis, contaminaci\u00f3n bacteriana... Haz clic y conoce los argumentos por los que ENFit es un sistema incompatible con la seguridad neonatal","breadcrumb":{"@id":"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/#primaryimage","url":"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2025\/09\/Portada-ENFit-incompatible-scaled.jpeg","contentUrl":"https:\/\/campusvygon.com\/es\/wp-content\/uploads\/sites\/7\/2025\/09\/Portada-ENFit-incompatible-scaled.jpeg","width":2560,"height":1700},{"@type":"BreadcrumbList","@id":"https:\/\/campusvygon.com\/es\/enfit-incompatible-seguridad-neonatal-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/campusvygon.com\/es\/"},{"@type":"ListItem","position":2,"name":"ENFit un sistema incompatible con la seguridad neonatal II"}]},{"@type":"WebSite","@id":"https:\/\/campusvygon.com\/es\/#website","url":"https:\/\/campusvygon.com\/es\/","name":"Campus Vygon Espa\u00f1a","description":"Un espacio para aprender sobre procedimientos y t\u00e9cnicas sanitarias de la mano de profesionales de referencia.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/campusvygon.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/campusvygon.com\/es\/#\/schema\/person\/00232c1410da1c96291ba4ad132d92a3","name":"Hiba Malek","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/campusvygon.com\/es\/wp-content\/plugins\/wp-user-avatar\/deprecated\/wp-user-avatar\/images\/wpua-96x96.png","url":"https:\/\/campusvygon.com\/es\/wp-content\/plugins\/wp-user-avatar\/deprecated\/wp-user-avatar\/images\/wpua-96x96.png","contentUrl":"https:\/\/campusvygon.com\/es\/wp-content\/plugins\/wp-user-avatar\/deprecated\/wp-user-avatar\/images\/wpua-96x96.png","caption":"Hiba Malek"},"description":"Responsable de las Unidades de Negocio de Terapias Intravasculares - Obstetricia, Neonatolog\u00eda y Nutrici\u00f3n Enteral - Vygon Espa\u00f1a","sameAs":["https:\/\/www.vygon.es\/","https:\/\/www.linkedin.com\/in\/hiba-malek-b7b4655a\/"],"url":"https:\/\/campusvygon.com\/es\/author\/hmalek\/"}]}},"_links":{"self":[{"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/posts\/5908","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/users\/33"}],"replies":[{"embeddable":true,"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/comments?post=5908"}],"version-history":[{"count":26,"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/posts\/5908\/revisions"}],"predecessor-version":[{"id":31581,"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/posts\/5908\/revisions\/31581"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/media\/47839"}],"wp:attachment":[{"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/media?parent=5908"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/categories?post=5908"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/campusvygon.com\/es\/wp-json\/wp\/v2\/tags?post=5908"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}